i-Clamp Two Way series - Installation Instructions

Two Way Series IDC Connector - Installation Instructions.

One wire IDC connector shown. Instructions also apply to two and three wire connectors.

STEP 1

IMPORTANT:   Turn off power to the circuit at main circuit breaker or fuse panel. All appropriate electrical codes should be followed on all electrical wiring. 

 

 

 

STEP 2

Select the proper i-Clamp based on the wire gauge being spliced. Do not close the top covers before inserting wiring, The i-Clamp can not be opened once closed.

 

 

STEP 3

Do not strip wires.

Insert wires into the side of the i-Clamp until it bottoms in the connector. Close the side of the connector that has wires by hand and squeeze until the wires are held in place.   Do not close the unused channel.

 
 
 

STEP 4

Lock the used channel of the connector using a pair of adjustable pliers. The top cover should be seated onto the base. Once closed, the connection is permanent and is tamper proof.  

Do not lock the unused channel of the connector 

 

 
 
STEP 5
 

Insert wires into the unused side of the i-Clamp until it bottoms in the connector. Close the connector by hand and squeeze until the wires are held in place.

 

 

STEP 6

Lock the connector using a pair of adjustable pliers.The top cover should be seated onto the base. Once closed, the connection is permanent and is tamper proof.

 

 

View product details